beautypg.com

Ua1 alarm – ADTRAN Tracer 2 x E1 User Manual

Page 49

background image

TRACER 2 x E1 User’s Manual

61280004L2-1C

Section 4 Troubleshooting

39

Recommended Actions:

1.

Check the far-end equipment for alarms or a LOS condition.

2.

Check the E1 connections at the far-end equipment.

3.

Reset the far-end equipment.

UA1 Alarm

This alarm is indicated on the E1A or E1B Status/Configuration/Loopback page.

Recommended Action

Possible Cause

(see list below)

The E1 equipment is sending unframed all 1’s ........................................... 1,2

Recommended Actions:

1.

Reset the upstream equipment and verify normal operation.

2.

Verify the presence of an E1 signal at the E1 monitor jack using an E1 test set.

I M P O R T A N T

If problems persist after you have followed the Recommended Actions, contact ADTRAN
Technical Support at (011) 256-963-8716.