Storing the last sum of weighings – RADWAG PUE C indicator User Manual
Page 40

EXI-01-04-06-14-GB
- 40 -
• Upon indication stabilization press
key, sum of the first and
second weighing is displayed
(„▲” pictogram in the upper right-hand
corner of the display):
• In order to finish the procedure of totalizing, press
(either with a
load on the pan or after taking it off):
• If the
key is pressed again while load is being placed on a
weighing pan, the sum of previously performed measurements is
deleted,
ZERO . Letter „P” will appear. The scale is ready for the next totalizing
procedure.
• If the
key is pressed again while load is not being placed on a
weighing pan, the sum of previously performed measurements is
deleted, the scale is ready for the next totalizing procedure.
14.8.3. Storing the last sum of weighings
After interrupting the procedure of totalizing (e.g. turning off the scale) it is
possible to restart with the last sum of weighings. In order to do it:
• enter
• last sum of weighings is seen on the display, the displayed value
comes from the scale memory,
• press
key in order to continue totalizing, the indication returns to
ZERO and the letter „P” appears on the display; next load may be
placed on the scale.
• press
,
or
key in order to finish totalizing, the letter „P”
appears on the display; the scale is ready for the next totalizing
procedure.