Gb 3. specifications 3. specifications, Specifications cph62i0 digital instrument – WIKA CPH62I0 User Manual
Page 11
11
WIKA operating instructions, model CPH62I0
11221801.02 02/2011 GB/D/F/E
GB
3. Specifications
3. Specifications
Specifications
CPH62I0 hand-held indicator (complete measuring chain)
Input
1 input for CPH62I0-S1
2 inputs for CPH62I0-S2
Pressure range
1)
bar
0.1
0.16 0.25 0.4
0.6
1.0
1.6
2.5
4.0
6.0
10
Over pressure safety
bar
1
1.5
2
2
4
5
10
10
17
35
35
Burst pressure
bar
2
2
2.4
2.4
4.8
6
12
12
20.5
42
42
Resolution (max.)
depending on pressure range
Pressure range
1)
bar
16
25
40
60
100
160
250
400
600
1000
Over pressure safety
bar
80
50
80
120
200
320
500
800
1200 1500
Burst pressure
bar
96
250
400
550
800
1000 1200 1700 2400 3000
Resolution (max.)
depending on pressure range
Type of pressure
gauge {absolute 0.25 up to 16 bar & vacuum on request}
Accuracy (measurement chain)
0.2 % FS ± 1 digit at reference temperature of 20 °C; optional: 0.1 %
Display
Large LCD display for display of 2 values and additional information
Range of display
max. -19999 up to 19999, depending on sensors used
Units
can be selected: bar, mbar, psi, Pa, kPa, MPa, mmHg and inHg (dependent on
range)
Specifications
CPH62I0 digital instrument
Functions via key press
Min-, Max-memory, Hold, Tare, Offset-correction, Logger (Start/Stop)
Functions via Menu
Min-, Max-alarm (visual), Sealevel (barom. air pressure), Power-Off-Function,
measurement rate: 4/sec (“slow“); > 1000/sec (“fast“); > 1000/sec unfiltered (“peak-
detect“) [via “peak-detect“ and min-/max-memory: pressure peaks of 1.5 msec can
be detected]
Data logger
- discrete value logger: up to 99 recordings incl. time via key press
- cyclic logger: automatic recording up to 10,000 values incl. time
- cycle time: selectable from 1 ... 3600 seconds
Interface (serial)
2)
USB or RS-232 interface via special interface cable
Analogue output
2)
0 ... 1 V; configurable (alternative instead of serial interface, selectable via menu)
Power supply
9 V-zinc-carbon battery, alternative: 9 V rechargeable battery or mains supply
Power consumption
cycle time slow: < 1.6 mA, fast: < 7.0 mA, Low-Power-Logger-Fct.: < 0.3 mA
Permissible
■
Working temperature
°C
-10 ... +50
■
Air humidity
% r. H. 0 ... 95 relative humidity without moisture condensation
■
Storage temperature
°C
-20 ... +70
Housing
Impact-resistant ABS, membrane keyboard, transparent panels with protective leather
case
Weight
g
approx. 160
Connection values
■
Max. voltage
DC V
Uo = 10,38
■
Max. strength of current
mA
Io = 93
■
Max. power
mW
Po = 240
■
Max. effective internal capacitance nF
Co = 1240
■
Max. effective internal inductance
Lo negligible
CE conformity
■
EMC directive
2004/108/EC, EN 61326 Emission (Group 1, Class B) and Immunity (portable
equipment)
■
ATEX directive
94/9/EC, Category 2G, Ignition protection type Ex ib IIC T4
1) In an oxygen version, a flush diaphragm model is not available. In an oxygen version model CPT62I0 is only available in gauge pressure ranges ≥ 0.25
bar with media temperatures between -10 … +50 °C and using stainless steel or Elgiloy® wetted parts.
2) For the intrinsically safe version, the use of the interface and analogue output is not permitted within an explosive atmosphere.
3) O-ring made of FKM/FPM or EPDM for flush diaphragm with integrated cooling element.
{}
Items in curved brackets are optional extras for additional price.