beautypg.com

Safety / 3. specifications, Specifications – WIKA Hydra-Gauge User Manual

Page 6

background image

6

WIKA operating instructions HYDRA-Gauge

9015329.01 08/2013 GB/D/F/E

GB

2. Safety / 3. Specifications

2.4 Labelling / Safety marks
Product label
(HYDRA-Gauge with switch contacts)

Explanation of symbols

Before mounting and commissioning the instrument with electronic contacts,

ensure you read the operating instructions!

CE, Communauté Européenne

Instruments bearing this mark comply with the relevant European directives.

Date of manufacture

3. Specifications

Permissible working conditions

Ambient temperature

+5 ... 60 °C

Process temperature

+5 ... 60 °C

The mechanical pressure gauge of the HYDRA-Gauge is overpressure safe up to the

full scale value for a short term. However working pressure should not exceed 2/3 of the

measuring range to guarantee a long service life of the pressure gauge.

In any case the maximum pressures and temperatures of the process connection

according to the following chart must not be exceeded. The resulting maximum

permissible working pressures might be lower than the instrument's measuring range.