Max. torque screws mounting strap
30 Nm
Max. torque screws socket external housing
5 Nm (3.688 lbf ft)
Weight approx.
4.2 … 4.5 kg (9.26 … 9.92 lbs), depending on
process fitting
Output variable
Output signal
digital output signal, format according to IEEE-754
Sensor address
126 (default setting)
Current value
10 mA, ±0.5 mA
Dynamic behaviour output
Run-up time
≤
20 s
I
63 %
100 %
t
t
1
t
2
Fig. 51: Presentation of the dead time t
1
and the time constant t
2
Version, nominal measuring range
Dead time t
1
Time constant t
2
Basic version 10 bar and 30 bar
100 ms
250 ms
Basic version 100 mbar
100 ms
180 ms
Basic version 500 mbar
100 ms
180 ms
Basic version, 3 bar
100 ms
180 ms
Basic version 16 bar and 40 bar
100 ms
180 ms
Isolating diaphragm version, all nominal measuring
ranges
Depending on the isolat-
ing diaphragm
Depending on the isolating
diaphragm
Response time with Profibus PA
-
cyclically approx.
10 ms
-
acyclically approx.
50 ms
Damping (63 % of the input variable)
0 … 999 s, adjustable
74
Differential pressure transmitter DPT10 - metal measuring diaphragm • Profibus PA
11 Supplement
37245
-EN
-100120