2 kramer protocol 3000, 1 protocol 3000 syntax, Kramer protocol 3000 – Kramer Electronics VP-8x8AK User Manual
Page 45: Protocol 3000 syntax, Section, Host message format, Device long response ( echoing command )

Kramer Protocol
41
41
14.2
Kramer Protocol 3000
This RS-232/RS-485 communication protocol lets you control the machine
from any standard terminal software (for example, Windows®
HyperTerminal Application) and uses a data rate of 115200 baud, with no
parity, 8 data bits, and 1 stop bit.
14.2.1
Protocol 3000 Syntax
Host message format:
Start Address (optional)
Body
Delimiter
#
Destination_id@
message
CR
Simple command (commands string with only one command without
addressing):
start
body
delimiter
#
Command SP Parameter_1,Parameter_2,…
CR
Commands string (formal syntax with commands concatenation and
addressing):
# Address@ Command_1 Parameter1_1,Parameter1_2,… |Command_2
Parameter2_1,Parameter2_2,… |Command_3
Parameter3_1,Parameter3_2,… |…CR
Device message format:
Start
Address (optional)
Body
Delimiter
~
Sender_id@
message
CR LF
Device long response (Echoing command):
Start
Address (optional)
Body
Delimiter
~
Sender_id@
command
SP
[
param1 ,param2
…]
result
CR
LF
CR = Carriage return (ASCII 13 = 0x0D)
LF = Line feed (ASCII 10 = 0x0A)
SP = Space (ASCII 32 = 0x20)