beautypg.com

Kramer protocol – Kramer Electronics VP-31KSi User Manual

Page 40

background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Kramer Protocol

36

Examples:

Recall Audio & Video connections

from preset 3

#PRCL 3

CR

~PRST-RCL 3 OK

CRLF

Show source of video output 2 from

preset 3

#PRST-VID? 3,2

CR

~PRST-VID 3: 4>2

CRLF

Operation commands

Command

Syntax

Response

Lock front panel

LOCK-FP LOCK-MODE
Short form: LCK LOCK-MODE

LOCK-FP LOCK-MODE RESULT

Get front panel locking state

LOCK-FP?

LOCK-FP LOCK-MODE

Parameters Description:

LOCK-MODE = Front panel locking state:

"0" or "off" to unlock front panel buttons.

"1" or "on" to lock front panel buttons.
Restart device

RESET

RESET OK

Switch to protocol 2000*

P2000

P2000 OK

* Protocol 2000 has command to switch back to ASCII protocol (like protocol 3000)

Audio parameters commands

Command

Syntax

Response

Set audio level in specific

amplifier stage.

AUD-LVL STAGE, CHANNEL, VOLUME
Short form: ADL STAGE, CHANNEL, VOLUME

AUD-LVL STAGE, CHANNEL,

VOLUME RESULT

Read audio volume level AUD-LVL? STAGE, CHANNEL

Short form: ADL? STAGE

AUD-LVL STAGE, CHANNEL,

VOLUME

Mute audio

MUTE MUTE-MODE

MUTE MUTE-MODE RESULT

Parameters Description:

STAGE =

"In","Out"

or

Numeric value (present audio processing stage). For example: "0" for Input level, "1" for Pre-Amplifier, "2" for Amplifier (Out)

etc.

CHANNEL = Input or Output #

VOLUME

= Audio parameter in Kramer units, precede minus sign for negative values.

++

increase current value

--

decrease current value

MUTE MODE = 1 – Mute

0 – Unmute

Machine info commands

Command

Syntax

Response

* Time settings commands require admin authorization