Kramer Electronics VP-28 User Manual
Page 39

VP-28 - Kramer Protocol
35
35
RESULT
Read audio mute state
MUTE?
MUTE MUTE-MODE
Set
talk
over
TLK
TALKOVER
_
MODE
TLK
TALKOVER_MODE
RESULT
Read
talk
over
TLK?
TLK
TALKOVER_MODE
Set
audio
mix
MIX
MIX-MODE
MIX
MIX-MODE RESULT
Read
audio
mix
MIX
?
MIX
MIX-MODE
Parameters Description:
STAGE =
"In","Out"
or
Numeric value (present audio processing stage). For example: "0" for Input level, "1" for Pre-Amplifier, "2" for
Amplifier (Out) etc.
CHANNEL = Input or Output #
VOLUME
= Audio parameter in Kramer units, precede minus sign for negative values.
++
increase current value,
--
decrease current value.
Machine info commands
Command
Syntax
Response
* Time settings commands require admin authorization
Read in\outs count
INFO-IO?
INFO-IO: IN INPUTS_COUNT, OUT OUTPUTS_COUNT
Read max presets count INFO-PRST?
INFO-PRST: VID PRESET_VIDEO_COUNT, AUD
PRESET_AUDIO_COUNT
Reset configuration to
factory default
FACTORY
FACTORY RESULT
Identification commands
Command
Syntax
Response
Protocol Handshaking
#
CR
~OK CRLF
Read device model
MODEL?
MODEL MACHINE_MODEL
Read device serial number
SN?
SN SERIAL_NUMBER
Read device firmware
version
VERSION?
VERSION MAJOR .MINOR .BUILD .REVISION
Set machine name
NAME MACHINE_NAME NAME MACHINE_NAME RESULT
Read machine name
NAME?
NAME MACHINE_NAME
Reset machine name to
factory default*
NAME-RST
NAME-RST MACHINE_FACTORY_NAME
RESULT
*Note: machine name not equal to model name. This name relevance for site viewer identification of specific
machine or for network using (with DNS feature on).
MACHINE_NAME = Up to 14 Alfa-Numeric chars.
*
Machine factory name = Model name + last 4 digits from serial number.