28
VP-28 - Default Parameters
9
Default Parameters
9.1
Default Communication Parameters
EDID
EDID data is passed between the connected output and the live input within each of the
DVI/ VGA, HDMI or DP groups
RS-232
Protocol 3000 (Default)
Baud Rate
115,200
Data Bits
8
Stop Bits
1
Parity
None
Command Format
ASCII
Example (Output 1 to Input 1)
#AV 1>1
Ethernet
To reset the IP settings to the factory reset values, power cycle the device while holding in
the Factory Reset button, located on the rear panel of the unit
IP Address
192.168.1.39
Subnet mask
255.255.255.0
Default gateway
192.168.1.1
TCP Port #
5000
UDP Port #
50000
Maximum UDP Ports
10
Maximum TCP Ports
4
9.2
Default Video/Audio Parameters
Item
Description
Switched input in all groups
1
Master audio gain
0dB
Mic audio gain
0dB