beautypg.com

9 default parameters, 1 default communication parameters, 2 default video/audio parameters – Kramer Electronics VP-28 User Manual

Page 32: Default parameters, Default communication parameters, Default video/audio parameters, 9default parameters

background image

28

VP-28 - Default Parameters

9

Default Parameters

9.1

Default Communication Parameters

EDID

EDID data is passed between the connected output and the live input within each of the

DVI/ VGA, HDMI or DP groups

RS-232

Protocol 3000 (Default)
Baud Rate

115,200

Data Bits

8

Stop Bits

1

Parity

None

Command Format

ASCII

Example (Output 1 to Input 1)

#AV 1>1

Ethernet

To reset the IP settings to the factory reset values, power cycle the device while holding in

the Factory Reset button, located on the rear panel of the unit

IP Address

192.168.1.39

Subnet mask

255.255.255.0

Default gateway

192.168.1.1

TCP Port #

5000

UDP Port #

50000

Maximum UDP Ports

10

Maximum TCP Ports

4

9.2

Default Video/Audio Parameters

Item

Description

Switched input in all groups

1

Master audio gain

0dB

Mic audio gain

0dB