TP-410 - Acquiring the EDID
23
23
9
Acquiring the EDID
The TP-410 can acquire the EDID information from a display connected to the
UXGA IN 15-pin HD connector on the TP-410, or acquire the default EDID.
To acquire the display EDID, do the following:
1. Connect the UXGA IN 15-pin HD connector to the input XGA connector of
the display, using a short cable.
The EDID is carried over pins 12 and 15 of the VGA connector. It is essential that the
cable used for capturing the EDID passes all 15 pins
2. Connect the display power.
3. On the TP-410, connect the power.
4. Press the EDID CAPTURE button.
5. Once the EDID STATUS blinks slowly several times, the EDID is captured.
6. Disconnect the display.
To acquire the default EDID, turn the unit OFF and then ON again while pressing
the Factory Reset button, located on the rear panel of the unit.
The default EDID is uploaded.
Note that when performing factory reset, other parameters are reset
to their default settings (see
Section 11.1
i