beautypg.com

7 the setup dip-switches, 1 setting the machine number, The setup dip-switches – Kramer Electronics TP-410 User Manual

Page 22: Setting the machine number, Figure 12: the address # dip-switches, 7the setup dip-switches

background image

TP-410 - The SETUP DIP-switches

19

19

7

The SETUP DIP-switches

The DIP-switches on the TP-410 set the machine number of the unit.

Moving a DIP-switch down turns the switch on, moving it up turns the
switch off. Changing any DIP-switch requires that you turn the TP-410
power off and then on again.

7.1

Setting the Machine Number

To control a unit remotely via RS-232, RS-485 or the Ethernet, each unit has to be

identified via its unique machine #. DIP-switches 1, 2, 3 and 4 set the machine

number (according to the table below).

Figure 12: The Address # DIP-switches

Add. #

DIP 1

DIP 2

DIP 3

DIP 4

Add. #

DIP 1

DIP 2

DIP 3

DIP 4

1

OFF

OFF

OFF

OFF

9

OFF

OFF

OFF

ON

2

ON

OFF

OFF

OFF

10

ON

OFF

OFF

ON

3

OFF

ON

OFF

OFF

11

OFF

ON

OFF

ON

4

ON

ON

OFF

OFF

12

ON

ON

OFF

ON

5

OFF

OFF

ON

OFF

13

OFF

OFF

ON

ON

6

ON

OFF

ON

OFF

14

ON

OFF

ON

ON

7

OFF

ON

ON

OFF

15

OFF

ON

ON

ON

8

ON

ON

ON

OFF

When using a single unit, set the unit to Address # 1.
Do not use the 1111 DIP-switch combination for normal operation

(see

Section 10

After setting a new machine number, turn the power off and then on again.

)

i

i