20

TP-410 - The SETUP DIP-switches

7.1.1

ETH Configuration

To configure the Ethernet parameters, set DIP-switches 1 to 4 to ON (ON-ON-ON-

ON), turn the power off and then turn the power on again.

Use the Kramer K-UPLOAD software to configure the Ethernet.

The latest version of K-UPLOAD and installation instructions can be
downloaded from the Kramer Web site at

www.kramerelectronics.com

7.2

Setting the RS-232/RS-485 Baud Rate DIP-switches

DIP-switches 5, 6 and 7 set the serial port baud rate.

In a multiple device configuration, all devices must be set to the same

baud rate.

Figure 13: TP-410 Baud Rate DIP-switches

Baud Rate

DIP-switch

5

6

7

1200

OFF

OFF

OFF

2400

ON

OFF

OFF

4800

OFF

ON

OFF

9600 (default)

ON

ON

OFF

19200

OFF

OFF

ON







i

i