Feature

Function

21

RS-485 (G,B,A)

Connect to the RS-485 controller.
Pins B (-) and A (+) are for RS-485; connect pin G to the cable shield (if required)

22

ETHERNET Connector

Connects to the PC or other Serial Controller through computer networking

23

FLASH

N/A (for factory use only)

24

FACTORY RESET

Turn the machine OFF using the power switch and then turn it ON while pressing the
FACTORY RESET button. The unit will power up and load its memory with the following
factory default definitions: default Ethernet settings (IP address: 192.168.1.39; TCP port
#: 5000 and UDP port #: 50000); RS-232 data is distributed to all 10 outputs and is
received by output 1 and the default EDID is acquired

25

SETUP DIP-switches

For setup of the unit (see

Section 7

26

)

Power Connector with Fuse

AC connector enabling power supply to the unit

27

Power Switch

Switch for turning the unit ON or OFF