Festo Контроллер крайних положений SPC11 User Manual
Page 33

2. Parameters of the SPC11 for the DSMI−...
2−7
Festo P.BE−SPC11−DSMI−EN en 0910b
2.3
Parameters for the DSMI−...−... in horizontal operation
DSMI−...−... in horizontal operation
DSMI−25−...
DSMI−40−...
DSMI−63−...
0
−4
]
MPYE−5−M5−010B
0
−4
]
MPYE−5−1/8LF−010B
0
−4
]
MPYE−5−1/8LF−010B
Mass
moment
of
iner
tia
[kgm
2
*
10
Amplification
stage
(A)
Cushioning
stage
(C)
S
ystem
parameters
(S)
Time
[s]
Mass
moment
of
iner
tia
[kgm
2
*
10
Amplification
stage
(A)
Cushioning
stage
(C)
S
ystem
parameters
(S)
Time
[s]
Mas
moment
of
inetria
[kgm
2
*
10
−
Amplification
stage
(A)
Cushioning
stage
(C)
S
ystem
parameters
(S)
Time
[s]
20
On request
80
10
14
13
0,75
300
17
17
5
0,64
40
10
21
12
0,66
160
13
19
13
0,78
600
20
21
5
0,71
60
12
23
12
0,65
240
15
21
13
0,79
900
21
23
5
0,73
80
13
24
12
0,70
320
16
23
13
0,82
1200
23
25
5
0,76
100
14
26
12
0,74
400
17
24
13
0,83
1500
24
26
5
0,78
120
15
27
12
0,74
480
18
25
13
0,83
2100
26
28
5
0,82
140
15
28
12
0,79
560
19
25
13
0,81
2400
26
28
5
0,84
160
16
29
12
0,78
640
19
27
13
0,89
3300
27
30
5
0,90
180
16
29
12
0,77
720
20
26
13
0,82
4000
28
31
5
0,90
200
17
30
12
0,82
800
20
27
13
0,84
4400
29
32
5
0,91
220
17
31
12
0,87
880
21
27
13
0,86
4900
29
32
5
0,94
240
18
32
12
0,87
960
21
28
13
0,87
5500
29
33
5
0,98
260
18
31
12
0,82
1040
21
29
13
0,90
6000
30
34
5
1,00
280
18
33
12
0,90
1120
22
29
13
0,92
300
19
32
12
0,84
1200
22
29
13
0,90