beautypg.com

Festo Контроллер крайних положений SPC11 User Manual

Page 25

background image

1. Summary of components

1−13

Festo P.BE−SPC11−DSMI−EN en 0910b

Mass load

S

Fit the mass load free of play.

S

Avoid mass loads with unfavourable natural vibration
features.

Please note
Natural vibrations of the mass load can cause faults.
Mount the mass load so that vibration is kept to a miniĆ
mum. Avoid mass loads on long flexible lever arms.

1

Favourable
natural vibrations

2

Unfavourable
natural vibrations
or not permitted

1

2

Fig. 1/6: Example: Favourable and unfavourable natural vibrations of the mass

Permitted mass moments of inertia see Parameters for the
DSMI−..." in chapter 2. The tables listed there contain all the
drive−valve combinations and mass moments of inertia perĆ
mitted for operating the DSMI−... with the Soft Stop SPC11.