Festo Контроллер крайних положений SPC11 User Manual
Page 32
1
2
3
4
2. Parameters of the SPC11 for the DSMI−...
2−6
Festo P.BE−SPC11−DSMI−EN en 0910b
The medium swivel times specified apply to a swivel angle of
270°. In individual cases it may be necessary to optimize the
positoning behaviour (see system manual)
DSMI−...−... in horizontal operation
DSMI−25−...
DSMI−40−...
0
−4
]
MPYE−5−M5−010B
0
−4
]
MPYE−5−1/8LF−010B
Mass
moment
of
iner
tia
[kgm
2
*
10
Amplification
stage
(A)
Cushioning
stage
(C)
S
ystem
parameters
(S)
Time
[s]
Mass
moment
of
iner
tia
[kgm
2
*
10
Amplification
stage
(A)
Cushioning
stage
(C)
S
ystem
parameters
(S)
Time
[s]
20
On request
80
10
14
13
0,75
40
10
21
12
0,66
160
13
19
13
0,78
1
Proportional directional control
valve required
2
Diameter of drive
3
Medium swivel times in seconds,
deviations usually lie within ± 70 ms
4
Maximum permitted mass moment of
inertia for adjacent parameter setting
Fig. 2/1: Explanation of table structure