beautypg.com

Troubleshooting, Problem possible cause(s) solution – SawStop ICS73600 User Manual

Page 73

background image

SawStop 10” Industrial Cabinet Saw 71

Troubleshooting

Problem

Possible Cause(s)

Solution

The motor will not start and both

LEDs on the switch box are off.

1. There is no power to the saw.

1. Ensure that the electrical supply to

the saw is on and that the correct

voltage is being supplied.

2. The disconnect switch is turned to

OFF.

2. Turn the disconnect switch to ON.

3. There is no brake cartridge installed

in the saw.

3. Install the brake cartridge.

4. The brake cartridge is defective.

4. Replace the brake cartridge with a

new cartridge.

5. For 415V, 480V and 600V saws, the

fuse in the side of the contactor box

has blown.

5. Check the fuse in the side of the

contactor box (only on a 415V, 480V

or 600V saw).

The motor will not start and at least

one LED on the switch box is on.

1. The safety system has detected a

system error and is displaying an

error code on the LEDs.

1. Consult the list of System Status

Codes to determine the cause of the

error and the corrective action.

2. The cartridge is defective.

2. Try a different brake cartridge.

3. The motor has overheated and

tripped the thermal overload switch.

3. Wait 10 minutes and try again.

The motor stopped unexpectedly

during use but the brake did not

activate.

1. The Start/Stop paddle was bumped.

1. Ensure the Start/Stop paddle is in

the OFF position and restart the saw.

2. The material being cut is overloading

the safety detection system (e.g.,

green or wet wood).

2. Use different wood or cut in Bypass

mode.

3. The safety system has detected a

system error and is displaying an

error code on the LEDs.

3. Consult the list of System Status

Codes to determine the cause of the

error and the corrective action.

4. Electrical power to the system was

lost at least temporarily.

4. Ensure that the electrical supply to

the saw is on and that the correct

voltage is being supplied.

5. A door interlock switch was released. 5. Ensure the belt access door and

motor cover are closed and the

interlock switches are actuated.

6. The cartridge is defective.

6. Try a different brake cartridge.

The brake activated even though

there was no accidental contact.

1. Some electrically conductive

material contacted the blade, arbor

or arbor pulley.

1. Make sure no metal or other

conductive material is touching the

blade, arbor or pulley. If you are

trying to cut a conductive material,

use Bypass mode.

2. The spreader or riving knife came

into contact with the blade.

2. Ensure that the spreader or riving

knife is accurately aligned and

securely clamped in place. There

should be a gap of at least 5-7mm

between the blade and the spreader

or riving knife

This manual is related to the following products: