56

SawStop 10” Industrial Cabinet Saw

Making Adjustments to Your Saw

Reposition the dial test indicator toward the front of the saw with the measurement arm about

1

/

2

inch inside

the front edge of the blade. Set the dial readout to zero. Slide the dial indicator mount toward the back of the

saw until the measurement arm is about

1

/

2

inch inside the rear edge of the blade. Note the readout.

If the readout is -2.5 times the first and second measurements, the v-bracket should be correctly positioned.

Otherwise, repeat the above process of adjusting the position of the v-bracket until the dial indicator at 0° reads

-2.5 times the difference between the first and second measurements.

Once the v-bracket is positioned correctly, tighten the bolts that attach the v-bracket to the rear trunnion. The

blade should now be parallel to the tilt axis.

Since the alignment of the blade has been changed, the table must now be realigned. Align the table as

described on page 47, using the precision alignment procedure. Once the table has been realigned, you can

check the parallelism of the blade to the tilt axis by tilting the blade to about 45° and measuring the alignment

between the blade and the miter slot. If the misalignment of the blade and the miter slot is less than 0.002 inch

at both 0° and 45°, then the blade is parallel to the tilt axis. If necessary, you can fine tune the alignment by

repeating the above procedure.

To create a positive misalignment, use a block of wood and a mallet to tap the left side of the elevation plate

(see Fig. 66). To create a negative misalignment, use a block of wood and a mallet to tap the edges of the

v-bracket (see Fig. 67).

Fig. 67

tap here

Fig. 66

tap here