beautypg.com

Setting up your saw – SawStop ICS73600 User Manual

Page 28

background image

26

SawStop 10” Industrial Cabinet Saw

Setting Up Your Saw

13. Access Door Interlock Switches:

As an additional safety feature, this saw is equipped with interlock switches on the belt access door and the

motor cover that prevent the motor from starting when either door is open. In the event that one of the doors is

opened while the motor is on, the corresponding interlock switch will cause the motor to shut down.

If either the access door or motor cover is open when you attempt to start the motor (or if a door opens when

the motor is already on), a System Status error will be displayed where the red LED is on solid and the green

LED flashes rapidly. If this occurs, you must close and latch the open door and then cycle the Main Power

switch on the Switch Box. (See page 28.)

The interlock switches are pre-positioned to be “closed” when the belt access door and motor cover are fully

closed. In the event one of the switches becomes misaligned, you can reposition the switch(es) as described

below to ensure all switches are closed when the access door and motor cover are closed.

Belt Access Door Interlock Switch: The interlock switch on the belt

access door is located inside the lower front edge of the access

door opening as shown in Fig. 25. The switch has a lever-type

actuator and is mounted on a bracket that is attached to the inside

of the cabinet by two screws.

If necessary, you can reposition the switch by loosening the screws

and moving the switch so that it is actuated when the belt access

door is fully closed. Re-tighten the screws to ensure the switch

remains in the correct position.

Motor Cover Interlock Switch: The interlock switch on the motor

cover is located near the lower rear edge of the motor cover

opening as shown in Fig. 26. This switch has a push-button type

actuator and is mounted to the inside of the cabinet by two screws.

An adjustable socket-head screw is threaded through a bracket on

the motor cover. This socket-head screw presses the switch closed

when the motor cover is closed.

If necessary you can reposition the switch by loosening the screws

and moving the switch. You can also adjust the position of the

socket-head screw by loosening the locking nut and turning the

screw. Re-tighten all hardware to ensure the switch continues to

operate correctly.

WARNING! The door interlock switches are connected to 208-240 VAC. Attempting to

disable or modify the interlock switches or wiring could result in a severe injury or electric

shock. Turn the Disconnect Switch to OFF before adjusting the interlock switches.

Fig. 25

Fig. 26

This manual is related to the following products: