Sv start velocity Page 36
Page 36

RMS Technologies
Page 36
Version 1.31
R101 Single Axis Driver/Indexer Manual
10/1/2007
SV
Start Velocity
Command or Query 250 to 15,000
Reads or sets the velocity used for the first step in a position move. Value based on
motor performance.
Command Example
#ASV500
Default value is 1,000