CP
Current Position
Current Position +/
–2,147,483,646
Command
or
Query.
Returns the absolute position of the axis if no value is passed. Valid after power
cycles if a Save Data Command is issued before power down. Can be used to set
current position value.
The units are steps at the current step resolution. (Value becomes invalid with step
resolution changes.)
The absolute position scale is set to zero by the Zero Position command (ZP) or the
execution of a Home Axis (HA) command.
Command Example
#ACP
#ACP1000