AC
Acceleration
Initial Acceleration (1 to 32767 steps/Sec ^2 *10^-2)
Command
or
Query.
Used to shape the acceleration and deceleration ramps of position moves, and the
rate of velocity change for velocity moves.
Does not affect any of the basic step and direction move operations
Command Example
#AAC10000
Sets
acceleration to 100 PPS^2.
Default value is 50