Sd save data – RMS Technologies R101 DRIVER/INDEXER User Manual
Page 32

RMS Technologies
Page 32
Version 1.31
R101 Single Axis Driver/Indexer Manual
10/1/2007
SD
Save Data
Command Only
This command causes a set of parameter values to be written to non-volatile
memory. On power up the last set of values written are set to be the parameter
initial values.
The parameters whose values are thus saved are:
My
Address
Absolute
Position
Velocity
Limit
Minimum
Velocity
Start
Velocity
Acceleration
Hold
Timeout
Step
Resolution
Run
Current
Hold
Current
Percent Fast Decay
Command Example
#ASD