RMS Technologies R101 DRIVER/INDEXER User Manual

Page 10

background image

RMS Technologies

Page 10

Version 1.31

R101 Single Axis Driver/Indexer Manual

10/1/2007

Example
Setting the Run Current (RI) to 1500mA (1.5A)

#ARI1500

//Sent Command

*ARI1500

//Received Reply


Setting the Current

There are two current settings on the R101.

1. Run Current (RI) – The peak current that the motor will be run at while in

motion.

2. Hold Current (HI) – The current that the motor will receive when idle.

*The default board address of ‘A’ is used in all examples, please see “MA” command for more
detail on addresses.


Examples:


To set Run Current to 2000mA (2.0A):

#ARI2000


To set Hold Current to 300mA (0.3A):

#AHI300



Setting Step Resolution

The R101 is capable of full stepping or 2x, 4x, and 8x microstepping.

Example:

To set Step Resolution to 4x microstepping:

#ASR4


Saving the Configuration


In order to have these settings retained upon a power cycle, the data must be saved.

The command to store these settings is “SD” (Save Data).

Example:


To save settings:

#ASD