Installation, Operation & Maintenance

HKV SERIES

Heat Controller, LLC

HKV168-300 Dimensional Data

NOTES:
1. All dimensions in inches (cm)
2. Water inlet and water outlet connections are available on either side (left or right) of the unit.

Installer must plug water inlet/outlet not being connected to.

3. Condensate drain is available on either side (left or right) of unit. Drain hose and drain

connection will be tied inside the unit. Installer will untie the drain hose, form trap, and connect to
the condensate drain hole of installer’s choice.

4. Electrical access is available on either side (left or right) of unit and is also available in the front

on the left or right side of the unit.

5. Overall Depth - Add 3.12”(8 cm) for 1”(2.5 cm) or 2”(5 cm) Filter Rack; 5.12” for 4” filter rack and

for FD, RD additional 1.06”(2.7cm) for supply air duct flange.

6. Overall cabinet height dimension does not include duct flange when in top discharge

configuration.

7. While access to all removable panels may not be required, installer should take care to comply

with all building codes and allow adequate clearance for future field service.

8. Units require 3 feet(91 cm) clearance for water connections, CAP, CSP, MSP and BSP service

access.

9. Side service access must be 2 feet(9.4 cm) on any side that connections are made. If no

connections are made on a side then service access can be 6 inches(1.5 cm) minimum.

10. Filter removal is from bottom of frame, allow 2 feet(9.4 cm) access for servicing.

LEGEND

1. Water inlet (see note 2)
2. Water outlet (see note 2)
3. Condensate drain (see note 3)
4. High voltage access (see note 4)
5. Low voltage access (see note 4)

168-240

300

2” FPT

2 1/2” FPT

2” FPT

2 1/2” FPT

1” FPT

1

3/8

” (3.49 cm)

7/8

” (2.2 cm)

BSP - Blower Service Panel
CAP - Control Access Panel
CSP - Compressor Access Panel

MSP - Motor Service Panel
NRP - Non Removable Panel

REAR RETURN TOP DISCHARGE (RR/TD)

FRONT RETURN TOP DISCHARGE (FR/TD)

FRONT RETURN REAR DISCHARGE (FR/RD)

Control Box

CSP

CSP

NRP

CAP

MSP

NRP

BSP

RETURN AIR

RETURN AIR

AIR OUT

AIR OUT

BSP

BSP

01

P

02

C

NRP

7.6

V

B

A

NOTE 5

F

D

G

D

E

S

N

U

T

K

M

L

3

2

1

R

Q

E

S

3

Control Box

CSP+MSP

NRP

BSP

RETURN AIR

RETURN AIR

AIR OUT

AIR OUT

F

L

3

1

2

3

CSP+CAP

7.6

UPA

4

5

4

4

5
4

K

M

NRP

BLOWER

ROTATION

Control Box

CSP+MSP

NRP

NRP

RETURN AIR

RETURN AIR

AIR OUT

AIR OUT

F

3

1

2

3

CSP+CAP

BSP

4

5

4

4

5
4

NRP

Control Box

CSP

NRP

CAP

MSP

NRP

AIR OUT

AIR OUT

NRP

E

NRP

1.7

F

D

G

D

2

1

3

4

5

4

4

5

4

CSP

REAR RETURN FRONT DISCHARGE (RR/FD)

RETURN

AIR

RETURN

AIR

BSP

Side Service Access
(See Notes 7 and 9)

Service Access
Front and Back

(See Notes 7 and 8)

3

ALL CONFIGURATIONS REQUIRE SERVICE ACCESS AREA

DESCRIBED IN NOTES 7, 8, 9, AND 10.

(See Notes 7 and 10)

UPA - Upper Pulley Access

Model

Overall Cabinet

Discharge Connections

Duct Flange

Water Connections

Electrical Knockouts

Return Air Connections

Using Return Air Opening

A

Depth

Note 5

B

Width

C

Height

D

Supply

Width

E

Supply

Depth

F

G

K

1

Water

Inlet

L

2

Water

Outlet

M

3

Condensate

N

O1

O2

P

Q

R

S

Return

Depth

T

Return

Height

U

V

168-

240

in.

cm.

34.0
86.4

106.7
270.9

79.0

200.7

17.5
44.5

17.6
44.6

17.8
45.1

31.3
79.4

31.0
78.7

3.0
7.6

27.0
68.6

25.6
65.1

31.0
78.7

38.0
96.4

34.6
87.8

1.0
2.5

3.0
7.6

48.0

121.9

32.4
82.2

44.6

113.3

2.7
6.9

300

in.

cm.

34.0
86.4

106.7
270.9

79.0

200.7

21.4
54.4

17.6
44.6

17.8
45.1

23.4
59.4

31.0
78.7

3.0
7.6

27.0
68.6

25.6
65.1

31.0
78.7

38.0
96.4

34.6
87.8

1.0
2.5

3.0
7.6

48.0

121.9

32.4
82.2

44.6

113.3

2.7
6.9

7