Blower performance, Hkv 168 blower performance, Hkv series – Comfort-Aire HKV300A User Manual
Page 34: Installation, operation & maintenance, Heat controller, llc
Installation, Operation & Maintenance
HKV SERIES
Heat Controller, LLC
33
HKV 168 Blower Performance
All Data is Wet Coil
Airflow
(SCFM)
ESP
Airflow (cfm) at External Static Pressure (in. wg)
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
1.10
1.20
1.30
1.40
1.50
4200
BHP
0.58
0.68
0.74
0.82
0.88
0.98
1.08
1.18
1.28
1.38
1.48
1.58
1.68
4200
Sheave/Mtr
B
B
B
B
A
A
A
A
A
A
A
A
C
4200
RPM
457
499
537
577
612
647
678
710
737
764
791
815
838
4200
Turns Open
6
5
3.5
2.5
6
5.5
4.5
3.5
3
2
1.5
1
3
4400
BHP
0.63
0.68
0.78
0.88
0.98
1.08
1.18
1.28
1.38
1.48
1.58
1.68
1.8
4400
Sheave/Mtr
B
B
B
B
A
A
A
A
A
A
A
C
C
4400
RPM
467
507
548
584
621
653
684
716
743
772
797
821
847
4400
Turns Open
5.5
4.5
3.5
2.5
6
5
4
3.5
2.5
2
1
3.5
3
4600
BHP
0.68
0.78
0.88
0.98
1.08
1.18
1.28
1.38
1.48
1.58
1.68
1.78
1.88
4600
Sheave/Mtr
B
B
B
B
A
A
A
A
A
A
A
C
C
4600
RPM
476
518
555
590
627
659
692
721
751
777
803
829
853
4600
Turns Open
5.5
4.5
3
2
5.5
5
4
3
2.5
1.5
1
3.5
2.5
4800
BHP
0.68
0.78
0.88
0.98
1.08
1.18
1.28
1.38
1.48
1.58
1.68
1.78
1.88
1.98
4800
Sheave/Mtr
B
B
B
B
B
A
A
A
A
A
A
C
C
C
4800
RPM
446
485
527
563
600
633
665
697
726
756
783
811
835
858
4800
Turns Open
6
5
4
3
1.5
5.5
4.5
4
3
2.5
1.5
4
3
2.5
5000
BHP
0.68
0.78
0.88
0.98
1.08
1.18
1.28
1.48
1.58
1.68
1.78
1.88
1.98
2.08
5000
Sheave/Mtr
B
B
B
B
B
A
A
A
A
A
A
C
C
E
5000
RPM
452
495
532
567
604
636
670
700
729
759
786
813
838
864
5000
Turns Open
6
5
4
2.5
1.5
5.5
4.5
3.5
3
2
1.5
4
3
2.5
5200
BHP
0.86
0.96
1.06
1.16
1.26
1.36
1.46
1.56
1.66
1.76
1.86
2.06
2.16
2.26
5200
Sheave/Mtr
B
B
B
B
A
A
A
A
A
A
A
E
E
E
5200
RPM
460
500
536
570
606
638
671
701
729
759
786
814
839
865
5200
Turns Open
6
4.5
3.5
2.5
6
5.5
4.5
3.5
2.5
2
1
4
3.5
2.5
5400
BHP
0.86
0.96
1.06
1.18
1.28
1.38
1.48
1.58
1.68
1.78
1.88
2.08
2.18
2.28
5400
Sheave/Mtr
B
B
B
B
A
A
A
A
A
A
A
E
E
E
5400
RPM
463
504
539
576
609
641
674
703
734
762
788
816
841
867
5400
Turns Open
5.5
4.5
3.5
2.5
6
5
4.5
3.5
2.5
2
1
4
3.5
2.5
5600
BHP
0.88
0.98
1.08
1.28
1.38
1.48
1.58
1.68
1.78
1.88
2.08
2.18
2.24
2.44
5600
Sheave/Mtr
B
B
B
B
A
A
A
A
A
A
D
E
E
E
5600
RPM
474
510
545
581
613
647
677
706
737
764
793
818
843
869
5600
Turns Open
5.5
4
3
2
6
5
4
3
2.5
1.5
1.5
4
3.5
2.5
5800
BHP
0.88
0.98
1.08
1.18
1.28
1.48
1.58
1.68
1.78
1.88
2.08
2.18
2.28
2.38
2.48
5800
Sheave/Mtr
B
B
B
B
B
A
A
A
A
A
D
D
E
E
E
5800
RPM
440
481
517
551
586
618
651
681
710
740
767
795
821
845
872
5800
Turns Open
6
5
4
3
2
5.5
4.5
4
3
2
2
1.5
3.5
3
2
6000
BHP
0.98
1.08
1.18
1.28
1.38
1.48
1.68
1.78
1.88
2.08
2.18
2.28
2.38
2.48
2.58
6000
Sheave/Mtr
B
B
B
B
B
A
A
A
A
D
D
D
E
E
E
6000
RPM
455
492
526
563
595
628
658
687
718
745
774
800
826
852
876
6000
Turns Open
6
5
3.5
2.5
1.5
5.5
4.5
3.5
3
2.5
2
1.5
3.5
3
2
6200
BHP
1.06
1.18
1.28
1.38
1.48
1.68
1.78
1.88
1.98
2.08
2.28
2.38
2.48
2.68
2.78
6200
Sheave/Mtr
B
B
B
B
B
A
A
A
A
D
D
D
E
E
E
6200
RPM
459
499
533
569
600
633
663
691
722
749
777
803
828
854
878
6200
Turns Open
5.5
4.5
3.5
2.5
1.5
5.5
4
3.5
2.5
2.5
2
1
3.5
3
2
6400
BHP
0.98
1.08
1.28
1.38
1.48
1.68
1.78
1.88
1.98
2.08
2.28
2.38
2.48
2.68
2.78
2.88
6400
Sheave/Mtr
B
B
B
B
B
A
A
A
A
D
D
D
D
E
E
E
6400
RPM
441
478
513
549
581
614
644
672
703
730
759
785
810
837
861
887
6400
Turns Open
6
5.5
4
3
2
6
5
4
3.5
3
2.5
1.5
1
3
2.5
2
6600
BHP
1.08
1.28
1.38
1.48
1.66
1.78
1.88
1.98
2.08
2.28
2.46
2.58
2.68
2.88
2.98
6600
Sheave/Mtr
B
B
B
B
B
A
A
A
D
D
D
D
E
E
E
6600
RPM
456
495
529
561
595
625
656
685
712
741
767
795
820
844
870
6600
Turns Open
6
5
3.5
2.5
2
5.5
4.5
4
3.5
3
2
1.5
3.5
3
2.5
6800
BHP
1.26
1.38
1.48
1.58
1.68
1.88
1.98
2.08
2.28
2.38
2.48
2.68
2.88
2.98
6800
Sheave/Mtr
B
B
B
B
A
A
A
D
D
D
D
D
E
E
6800
RPM
471
506
539
574
604
633
664
692
721
747
773
800
825
851
6800
Turns Open
5.5
4.5
3.5
2.5
6
5.5
4.5
4
3
2.5
2
1
3.5
2.5
7000
BHP
1.28
1.48
1.58
1.68
1.88
1.98
2.08
2.28
2.46
2.58
2.68
2.88
2.98
7000
Sheave/Mtr
B
B
B
B
A
A
D
D
D
D
D
D
E
7000
RPM
486
520
555
586
615
647
674
704
730
756
784
808
835
7000
Turns Open
5
4
3
2
6
5
4.5
3.5
3
2.5
1.5
1
3
A = Standard Static/Standard Motor, B = Low Static/Standard Motor, C = High Static/Standard Motor, D = Standard Static/Large Motor, E = High Static/Large Motor
Unit factory shipped with standard static sheave and drive at 2.5 turns open. Other speed require field selection.
For applications requiring higher static pressures, contact your local representative. Performance data does not include drive losses and is based on sea level conditions.
Do not operate in black regions. All airflow in rated at lowest Voltage if unit is dual Voltage rated, i.e. 208V for 208-230V units.
Blower Performance