Blower performance, Hkv 240 blower performance, Table continued from previous page – Comfort-Aire HKV300A User Manual

Page 38: Hkv series, Installation, operation & maintenance, Heat controller, llc

background image

Installation, Operation & Maintenance

HKV SERIES

Heat Controller, LLC

37

HKV 240 Blower Performance

9000

BHP

2.98

3.08

3.28

3.48

3.68

3.88

4.08

4.18

4.28

4.48

4.68

4.88

5.08

5.28

5.48

5.68

9000

Sheave/Mtr

A

A

A

A

A

A

A

A

A

C

C

C

E

E

E

E

9000

RPM

653

679

707

731

755

779

804

826

848

870

893

914

935

955

978

997

9000

Turns Open

6

5

4.5

4

3.5

3

2.5

2

1.5

5.5

5

4.5

4

3.5

2.5

2

9200

BHP

3.18

3.28

3.48

3.68

3.88

4.08

4.28

4.48

4.68

4.78

4.88

5.08

5.28

5.48

5.68

5.88

9200

Sheave/Mtr

A

A

A

A

A

A

A

A

A

C

C

E

E

E

E

E

9200

RPM

668

694

721

745

768

791

816

838

860

883

904

925

945

967

987

1007

9200

Turns Open

5.5

5

4

3.5

3

2.5

2

1.5

1

5

4.5

4

3.5

3

2.5

2

9400

BHP

3.48

3.68

3.78

3.88

4.08

4.28

4.48

4.68

4.88

5.08

5.28

5.38

5.48

5.68

5.88

6.08

9400

Sheave/Mtr

A

A

A

A

A

A

A

A

C

E

E

E

E

E

E

E

9400

RPM

683

711

735

758

782

806

828

850

871

894

915

935

955

977

997

1016

9400

Turns Open

5

4.5

4

3.5

3

2.5

2

1

5.5

5

4.5

4

3.5

3

2

2

9600

BHP

3.68

3.88

3.98

4.08

4.28

4.48

4.68

4.88

5.08

5.28

5.48

5.68

5.88

6.08

6.28

6.48

9600

Sheave/Mtr

A

A

A

A

A

A

A

A

E

E

E

E

E

E

E

E

9600

RPM

698

725

749

772

795

819

836

862

883

906

926

946

968

987

1007

1025

9600

Turns Open

4.5

4

3.5

3

2.5

2

1.5

1

5

4.5

4

3.5

3

2.5

2

1.5

9800

BHP

3.88

4.08

4.28

4.48

4.68

4.88

4.98

5.08

5.28

5.48

5.68

5.88

6.08

6.28

6.48

6.68

9800

Sheave/Mtr

A

A

A

A

A

A

A

E

E

E

E

E

E

E

E

E

9800

RPM

715

739

762

785

810

831

853

874

896

917

937

956

978

997

1016

1035

9800

Turns Open

4.5

4

3.5

3

2.5

1.5

1

5.5

4.5

4.5

3.5

3

3

2.5

2

1.5

10000

BHP

4.08

4.28

4.48

4.68

4.88

5.08

5.28

5.48

5.68

5.88

6.08

6.28

6.48

6.68

6.78

6.88

10000

Sheave/Mtr

A

A

A

A

A

E

E

E

E

E

E

E

E

E

E

E

10000

RPM

730

753

776

798

822

844

865

885

908

928

948

967

988

1007

1026

1044

10000

Turns Open

4

3.5

3

2.5

2

6

5.5

5

4.5

4

3.5

3

2.5

2

1.5

1

A = Standard Static/Standard Motor, B = Low Static/Standard Motor, C = High Static/Standard Motor, D = Standard Static/Large Motor, E = High Static/Large Motor
Unit factory shipped with standard static sheave and drive at 2.5 turns open. Other speed require field selection.
For applications requiring higher static pressures, contact your local representative. Performance data does not include drive losses and is based on sea level conditions.
Do not operate in black regions. All airflow in rated at lowest Voltage if unit is dual Voltage rated, i.e. 208V for 208-230V units.

Table Continued from Previous Page

All Data is Wet Coil

Blower Performance