ATEX Identification

For a pumping unit (pump, seal, coupling, motor and pump accessories) to be certified for use in an ATEX classified
environment, the proper ATEX identification must be present. The ATEX tag will be secured to the pump or the
baseplate on which it is mounted. A typical tag will look like this:

II 2 G/D X

The CE and the Ex designate the ATEX compliance. The code directly below these symbols reads as follows:

II ------------

 Group 2

2 -------------

 Category 2

G/D ------------

 Gas and Dust present

X ------------ Temperature class, can be T1 to T6 (see following table)

Maximum Process Temperature to achieve desired T rating

T Rating per EN 1127-1

Maximum Surface

Temperature in Celsius

Maximum Process

Temperature in Celsius

T1

450

410

T2

300

260

T3

20

0

165

T4

135

100

T5

100

65

T6

85

50

The code classification marked on the equipment should be in accordance with the specified area where the

equipment will be installed. If it is not, please contact your ITT/Goulds representative before proceeding.

Intended Use

The ATEX conformance is only applicable when the pump unit is operated within its intended use. All instructions

within this manual must be followed at all times. Operating, installing or maintaining the pump unit in any way that is

not covered in this manual can cause serious personal injury or damage to the equipment. This includes any

modification to the equipment or use of parts not provided by ITT/Goulds. If there is any question regarding the

intended use of the equipment please contact an ITT/Goulds representative before proceeding.