Pump Safety Tips
Safety Apparel:
•
Insulated work gloves when handling hot bearings
or using a bearing heater
•
Heavy work gloves when handling parts with sharp
edges, especially impellers
•
Safety glasses (with side shields) for eye protection,
especially in machine shop areas
•
Steel-toed shoes for foot protection when handling
parts, heavy tools, etc.
•
Other personal protective equipment to protect
against hazard/toxic fluids
Coupling Guards:
•
Never operate a pump without a V-belt guard
properly installed
Flanged Connections:
•
Never force piping to make a connection with a
pump
•
Use only fasteners of the proper size and material
•
Ensure there are no missing fasteners
•
Beware of corroded or loose fasteners
Operation:
•
Do not operate below minimum rated flow, or with
discharge valves closed
•
Do not open vent or drain valves, or remove plugs
while system is pressurized
Maintenance Safety:
•
Always lockout power
•
Ensure pump is isolated from system and pressure
is relieved before disassembling pump, removing
plugs, or disconnecting piping
•
Use proper lifting and supporting equipment to
prevent serious injury
•
Observe proper decontamination procedures
•
Know and follow company safety regulations
•
Never apply heat to remove impeller
•
Observe all cautions and warnings highlighted in
pump instruction manual
Safety Definitions
These pumps have been designed for safe and reliable operation when properly used and maintained in accordance
with instructions contained in this manual. A pump is a pressure containing device with rotating parts that can be
hazardous. Operators and maintenance personnel must realize this and follow safety measures. Goulds pumps
shall not be liable for physical injury, damage or delays caused by a failure to observe the instructions in this manual.
The following symbols are used to denote special attention:
Electrical Hazard. Particular care must be taken when electrical power source to the equipment is
energized.
Warning. Operating procedure, practice etc which, if not correctly followed, could result in personal injury or
loss of life
Caution. Operating procedure, practice etc which if not followed could result in damage or destruction of
equipment
ATEX. If equipment is to be installed in a potentially explosive atmosphere and these procedures are not
followed, personal injury or equipment damage from an explosion may