Par
Description
Units
P0‐26
Energy Consumption kWh Meter
kWh
Displays the amount of energy consumed by the drive in kWh. When the value reaches 1000, it is reset back to 0.0, and the value of
P0‐27 (*MWh meter) is increased.
P0‐27
Energy Consumption MWh Meter
MWh
Displays the amount of energy consumed by the drive in MWh.
P0‐28
Software Version and Checksum
‐
Displays the software version of the drive
P0‐29
Drive Type
‐
Displays the type details of the drive
P0‐30
Drive Serial Number
‐
Displays the unique serial number of the drive.
P0‐31
Drive Lifetime Operating Time
HH:MM:SS
Displays the total operating time of the drive. The first value shown is the number of hours. Pressing the Up key will display the
minutes and seconds.
P0‐32
Drive Run Time Since Last Trip (1)
HH:MM:SS
Displays the total operating time of the drive since the last fault occurred. The first value shown is the number of hours. Pressing the
Up key will display the minutes and seconds.
P0‐33
Drive Run time Since Last Trip (2)
HH:MM:SS
Displays the total operating time of the drive since the last fault occurred. The first value shown is the number of hours. Pressing the
Up key will display the minutes and seconds.
P0‐34
Drive Run Time Since Last Disable
HH:MM:SS
Displays the total operating time of the drive since the last Run command was received. The first value shown is the number of
hours. Pressing the Up key will display the minutes and seconds.
P0‐35
Drive Internal Cooling Fan Total Operating Time
HH:MM:SS
Displays the total operating time of the Drive internal cooling fans. The first value shown is the number of hours. Pressing the Up key
will display the minutes and seconds. This is used for scheduled maintenance information
P0‐36
DC Bus Voltage Log (256ms)
V
P0‐37
DC Bus Voltage Ripple Log (20ms)
V
P0‐38
Heatsink Temperature Log (30s)
°C
P0‐39
Ambient Temperature Log (30s)
°C
P0‐40
Motor Current Log (256ms)
A
The above parameters are used to store the history of various measured levels within the drive at various regular time intervals prior
to a trip. The values are frozen when a fault occurs and can be used for diagnostic purposes – see section for further information.
P0‐41
Critical Fault Counter – Over Current
‐
P0‐42
Critical fault counter – Over Voltage
‐
P0‐43
Critical fault counter – Under Voltage
‐
P0‐44
Critical fault counter – Over Temperature
‐
P0‐45
Critical fault counter – Brake Transistor Over Current
‐
P0‐46
Critical fault counter – Ambient Over Temperature
‐
These parameters contain a record of how many times certain critical faults have occurred during a drives operating lifetime. This
provides useful diagnostic data
P0‐47
Reserved
‐
Reserved Parameter
P0‐48
Reserved
‐
Reserved Parameter
P0‐49
Modbus RTU Communication Error Counter
‐
This parameter is incremented every time an error occurs on the Modbus RTU communication link. This information can be used for
diagnostic purposes.
P0‐50
CAN Open Communication Error Counter
‐
This parameter is incremented every time an error occurs on the CAN Open communication link. This information can be used for
diagnostic purposes.