Step One

Do not locate suction outlets on seating areas
or on the brackets for such areas.

Step Two

Cut a 3.5

hole into the spa wall for a flat gasket.

Cut a 3.63

hole into the spa wall for a L gasket.

Step Four

Place gasket on wall fitting

Step Five

Place wall fitting through the hole

Step Nine

Tighten nut securely

Step Ten

Glue adaptor into wall fitting
socket with 0.75” smooth barb or
0.5” socket facing up

Step Eleven

Attach schedule 40 plumbing to the
2.0” or 2.50” adaptor

Step Twelve

A tubing resistant to kink or
pinching shall be used
(or provided) for use with the
suction adaptor. Attach the
provided tubing 0.75” to the
smooth barb on the adaptor
fitting with glue and a clamp
to secure.

Step Six

Orient the tab down / Note
wording “INSTALL ARROW UP.”

Step Three

Back face the backside of the wall as
necessary so that it is parallel to the
front side of the wall.

Step Eight

Thread nut onto the wall fitting

Step Seven

Place the compensating ring on the
wall fitting with the flat side against
the wall.

Step Thirteen

Run 0.75” vinyl tubing above the
highest possible water level,
creating a Hartford loop, and
attach securely.

Step Fourteen

Place suction cover on wall fitting
with blank portion (no holes)
pointed down. The keyway
on inside cover must match with
tab on wall fitting.

Step Fifteen

Insert stainless steel screw in
cover and tighten securely.
(Do not over-tighten plastic
will strip).

VGB 2008

211 GPM Suction Flow

Installation Instructions

40747 Rev A May 21, 2012

Patented under U.S. Patent No. 8,191,183.

©2012 Balboa Water Group. All rights reserved.