Additional Settings

Hold Mode - M037*

Hold Mode is used to disable the pumps during service functions like cleaning or replacing the filter. Hold Mode will last
for 1 hour unless the mode is exited manually. If spa service will require more than an hour, it may be best to simply shut
down power to the spa.

Drain Mode

Some spas have a special feature that allows Pump 1 to be employed when draining the water.
When available, this feature is a component of Hold Mode.

Utilities

The Utilities Menu contains the following:

A/B Temps

When this is set to On, the main screen will display sensor A and sensor B temperatures simultaneously. Sensor A is at
the opposite end of the heater from sensor B.

Demo Mode

Demo Mode is not always enabled, so it may not appear. This is designed to operate several devices in a sequence in
order to demonstrate the various features of a particular hot tub.

Fault Log

The Fault Log is a record of the last 24 faults that can be
reviewed by a service tech.

Use the Up and Down buttons to view each of the Faults.

When Priming Mode shows in the Fault Log, it is not a fault.
Rather, it is used to keep track of spa restarts.

GFCI Test
(Feature not available on CE rated systems.)

Your systems may have GFCI configured in one of three ways:

1. GFCI test is not enabled

2. Manual GFCI test is enabled but automatic GFCI test is not enabled

3. Both manual and automatic GFCI tests are enabled. The automatic test will happen within 7 days of the spa be-

ing installed and if successful will not repeat. (If the automatic test fails it will repeat after the spa is restarted.)

GFCI Test will not appear on the screen if it is not enabled. This screen allows the GFCI to be tested manually from the
panel and can be used to reset the automatic test feature. (See Page 20)

Fault Log

Back

Entry

2

Message Code M026
1 Days Ago 2:21PM
Rest Mode
High Range
Set Temp 104°F
Sensors: A: 100 B: 96

Message:
Sensors are out of sync

*M0XX is a Message Code. Codes like this will be seen in the Fault Log