beautypg.com

Adjusting filtration, Main filtration, Filter cycle 2 - optional filtration – Balboa Water Group spaTouch Menu Panel User Manual

Page 13: Circulation pump modes, Purge cycles, The meaning of filter cycles

background image

42256_A

01-09-14

13

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

Adjusting Filtration

Main Filtration

Using the same adjustment as Setting the Time, Filter Cycles are set using a start time and a duration. Each setting
can be adjusted in 15-minute increments. The panel calculates the end time and displays it automatically.

Filter Cycle 2 - Optional Filtration

Filter Cycle 2 is OFF by default. This displays as “No”. When Filter Cycle 2 is ON it displays as “Yes”.

Press “Yes” or “No” to toggle Filter Cycle 2 ON or OFF. When Filter Cycle 2 is ON, it can be adjusted in the same manner as
Filter Cycle 1.

It is possible to overlap Filter Cycle 1 and Filter Cycle 2, which will shorten overall filtration by the overlap amount.

Circulation Pump Modes

Some spas may be manufactured with Circ Pump settings that allow programming filtration cycle duration. Some circ Modes
are pre-programmed to operate 24 hours a day and are not programmable. Refer to the spa manufacturer’s documentation
for any Circ Mode details.

Purge Cycles

In order to maintain sanitary conditions, as well as protect against freezing, secondary water devices will purge water from
their respective plumbing by running briefly at the beginning of each filter cycle.

If the Filter Cycle 1 duration is set for 24 hours, enabling Filter Cycle 2 will initiate a purge when Filter Cycle 2 is pro-
grammed to begin.

The Meaning of Filter Cycles

1. The heating pump always runs during the filter cycle*

2. In Rest Mode, heating only occurs during the filter cycle

3. Purges happen at the start of each filter cycle

* For example, if your spa is set up for 24/hour circulation except for shutting

off when the water temperature is 3˚F/1.3˚C above the set temperature, that
shutoff does not occur during filter cycles.

Filter Cycles

Back

Filter Cycle 1
Starts at 12:00 AM
Runs 0 HR 0 Min
Ends at 12:00 AM

Filter Cycle 2 No
Starts at 12:00 AM
Runs 0 HR 0 Min
Ends at 12:00 AM

Filter Cycles

Back

Filter Cycle 1
Starts at

6:15

AM

Runs

3

HR 0 Min

Ends at 9:15 AM

Filter Cycle 2 No
Starts at 12:00 AM
Runs 0 HR 0 Min
Ends at 12:00 AM

Cancel

Save