Troubleshooting – Balboa Water Group Quiet-Flo Blower (Australian) User Manual
Page 2

Symptom
Reason
Solution
Bl
ower will not operate or
operates erratically.
(Replacement Quiet-Flo
Blowers may be purchased
from a Balboa Water Group
retailer or authorised BWG
service dealer.)
N
o power at
power
source.
Make sure fuse is not blown.
UÊ
Make sure RCD is not tripped. Reset.
UÊ
If still no power, consult qualified electrician.
UÊ
Power outlet is function-
ing properly, but blower
is still not working.
Disconnect power from main breaker.
UÊ
Recheck power cord for damage or loose
UÊ
connection. Have a qualified service
technician replace the cord.
If the motor has malfunctioned, replace the
UÊ
blower.
Low voltage.
Is there proper voltage?
Contact qualified electrician service technician.
UÊ
Moisture/water present
insid
e neck assembly.
Disconnect power from main breaker.
UÊ
Check that the mounting of the blower is in
UÊ
accordance with instructions.
D
UÊ
amaging back flow of water into the blower
may have occurred because of the following
have NOT been installed properly:
a) Two safety check valves between the outflow
of the blower and spa water, or
b) A Hartford loop with air lines placed as high
as possible above the water line, or
c) Blower installed at least 46cm (18”) above
the water level.
d) Blower hoses have not been connected
properlly to the plumbing.
If any of these conditions are suspected,
UÊ
contact the spa pool manufacturer.
Moisture/water/vermin
damage in the blower’s
housing cavity/casing.
Disconnect power from main breaker.
UÊ
Check mounting of blower is in accordance
UÊ
with instructions.
Visually inspect surrounding for undue water.
UÊ
If moisture is present and unit is inoperable,
blower needs replacing.
Prior to installing new blower, verify that there
UÊ
is no source of water spraying at/or on the
blower.
Contact the
UÊ
spa pool manufacturer.
TROUBLESHOOTING
Page 2