Page

5-61

XTRAEDIT CONFIGURATION

If the user selects None, the Configuration/Status Page will not be printed

under any conditions, except when the user selects Mode C using the

Mode Selector button on the top panel of the XLI. If the user selects

Always, the Configuration/Status Page will be printed upon power up,

when requested within a document, when an error condition occurs, and

when the user selects Mode C. The other choices restrict the printing of

the Configuration/Status Page to a smaller set of conditions.

Error Level
This option is used in conjunction with the Job Sheet option. It is used to

determine which level of error qualifies as an error for the purpose of

printing a Configuration/Status Page. It also determines, when a

Configuration/Status Page is printed, which errors are reported on the

page. The default choice is Parse. The user can also choose among

Critical, Fatal, Implementation and Superficial.
If the user chooses Fatal, the only errors reported will be those that

prevent the document from being printed. Critical errors are those will

cause the document to print incorrectly, such as missing fonts or forms.

Parse errors are those caused by incorrect or incomplete XES commands.

Implementation errors are due to the XLI implementation of XES

commands. Superficial errors are those that will not affect printed output.

Each choice is inclusive of the choice(s) above it.

Undo Settings — Alt-U

Changes to the configuration of the XLI are not installed (saved in the

XLi’s flash memory) until the user either quits XTRAEDIT, or uses the

Install Settings Now or Install As New Configuration commands. Undo

Settings is a command that will cancel all changes to the configuration of

the XLI that were made since the previous installation of XLI

configuration settings.
This command will not undo Font menu commands such as Load Font,

Delete Font, Pack XLI Memory and Non-Shrinkable Fonts, nor will it

undo the Delete Configuration command. These commands write

information to the XLI memory immediately.

Install Settings Now — Alt-I

Changes to the configuration of the XLI are not installed (saved in the

XLi’s flash memory) until the user either quits XTRAEDIT, or uses the

Install Settings Now or Install As New Configuration commands. Use this

command to save any changes to the current configuration.