beautypg.com

Cleaning sequences – Karcher HKF 200 K2 User Manual

Page 38

background image

-

18

The interior of the tank must be com-
pletely emptied prior to cleaning.

The interior of the tank may contain a
maximum of 25 l residual materials of
Groups II and III as well as the liquid
products of Group I.

In addition to its cleaning function,
steam also has a protective function (in-
ertisation) during the cleaning of flam-
mable products. Especially with
products of Group II and containers with
diameters of more than 3 m, a steaming
should be performed as a potective
measure in adherence with local laws.

Cleaning sequences

Residual materials

Cleaning liquids

Product

1st cleaning step

2nd cleaning step

3rd cleaning step

Products in Group I

Motor oils

Water vapour

max. 1.2 MPa (12 bar), 191 °C

Heating oil "EL"

Flammability and viscosity as

per DIN 51603

25/40 °C

Water

75/85 °C

M 100

M 40

F 12

F 5

Heating oil

Kreosot/tar oil

Paraffin oil

Fatty acid

Phenol

Products in Group II

acetone

Water vapour

max. 1.2 MPa (12 bar), 191 °C

Cold water

max. 20 °C

--

Methylstyrole

Diesel

petrol

Products in Group III

Ammonium (solution 10-15%)

Cold water

max. 20 °C

--

--

Soda, calcinated (solution 42%)

Hydrochloric acid (solution 35%)

Nitric acid (solution 72%)

Sulfuric acid (solution 92%)

38

EN