beautypg.com

ROTHENBERGER Modul ROLOC PLUS User Manual

Page 19

background image

ENGLISH

17

e) Under abusive conditions, liquid may be ejected from the battery; avoid contact. If

contact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek medical

help. Liquid ejected from the battery may cause irritation or burns.
6) Service
Have your power tool serviced by a qualified repair person using only identical re-

placement parts. This will ensure that the safety of the power tool is maintained.

2.

Technical Data

Functioning Range (with ROSCOPE 25/16):
(depth) .............................0.6 – 1.8m (2’ - 8’)
(horizontal) ......................0 – 4.5m (0’ – 15’)
Deviation and maximum range always depending on SONDE, soil, pipe material etc.
Frequencies .........................512 Hz, 640 Hz, 50/60 Hz passive, 33 KHz active/passive
Estimated Battery Life ..........3-5 hours

(See battery specification above for ROSCOPE 1000/i2000)

Weight ................................3 lbs. 4.91 oz. / 1.5 Kg
Dimensions:
Length ................................25” / 63.5 cm
Width .................................12.5” / 31.75 cm
Height .................................4” / 10.16 cm
Operating Environment:
Temperature ........................0°C to 40°C (32°F to 104°F)
Humidity .............................Maximum of 95% non-condensing (display unit)
Storage Temperature ...........–20°C to 60°C (-4°F to 140°F)

3.

Function of the unit

3.1

Description

The ROLOC PLUS is intended to be used with the Module 25/16 and the ROSCOPE 1000/i2000

handheld viewing device. The ROSCOPE 1000/i2000 handheld viewing device is disconnected

from the Module 25/16 once the blockage is identified and located, and it is then reattached to

the ROLOC PLUS line detection device to locate the transmitting SONDE on the Module 25/16

imager reel. All (3) units, when used together, give the professionsl the means to accurately iden-

tify and locate the exact position of a damaged or blocked pipe or drain line.
Note: Any other transmitting SONDE with compatible frequencies can also be located by using

the Module ROLOC PLUS with the ROSCOPE handheld.

IMPORTANT NOTE: It is always recommended to contact your local

utility (BEFORE YOU DIG) to verify the location of any potentially

harmful buried wires or gas lines.

PLEASE NOTE: “Not” all lines will transmit an appropriate signal

such that this (or any other) line tracer can detect them, and other

utilities, such as gas lines, have “no” electrical charge what so

ever. This tool should “not” take the place of standard safety

protocol.

Always contact your local utility before you dig to

avoid potentially harmful or fatal mistakes!

3.2

Standard Equipment

The ROLOC PLUS (No. 1500000057) comes with the following items (Figure 1):
- Module ROLOC PLUS (ROSCOPE 1000/i2000 sold seperatey)
- Manual
- Blow Mold Case