beautypg.com

Maintenance – Blodgett SC-E Series User Manual

Page 15

background image

OM-SC-E 13

Maintenance

The steamer is designed for minimum maintenance, and no user adjustments should be

necessary. Certain parts may need replacement after prolonged use. If there is a need for

service, only authorized representatives should perform the work. Always supply water

with a low mineral count that meets the standards outlined in the Water Conditioning

section of this manual.

If steam or condensate is seen leaking from around the door, take the following steps:

1. Check the door gasket. Replace if it is cracked or split.

2. Inspect the cooking chamber drain to be sure it is not blocked.

3. Adjust the latch pin to allow for changes that might occur as the gasket ages.

a.

Loosen the lock nut at the base of the latch pin. Turn the latch pin ¼ turn

clockwise, and re-tighten the lock nut.

b. After adjustment, run the unit to test for further steam leakage.

c. If there is still leakage, repeat the adjustment.

d. Continue adjusting the pin clockwise until the door fits tightly enough to

prevent leakage.

NOTE

THE UNIT CONTAINS NO FUSES THAT SHOULD

BE REPLACED BY THE OPERATOR.