beautypg.com

Operation – Blodgett SC-E Series User Manual

Page 11

background image

OM-SC-E 9

Operation

NOTE: Before the steamer can be operated as described in this section, the pilot

burner flame must be established. For details see the Initial Start-Up section and the

Automatic Operation of Pilot on previous page.

A. Controls

Operator controls are on the front right of the unit. The control panel on new

models has the following touch pads and indicator lights:

• The ON/OFF touch pad gets the steamer ready for use, or shuts it off.

• The READY indicator light shows that the steam generator is at standby

temperature and the cavity is hot enough to begin steaming.

• The DELIME indicator light is lit when the unit is operating in the cleaning

mode.

• The SERVICE indicator light shows when the water level probes have stopped

working, and need to be cleaned (normally an indication of lime deposits).

When one probe is not working, the DELIME light flashes briefly every few

seconds. If both probes fail the SERVICE light will come on continuously and

the beeper will sound.

• The HI TEMP indicator light comes on when the steam generator is too hot.

The unit will automatically shut off, and cannot be turned on again until the

steam generator cools and the HI TEMP indicator light goes out.

• The TIMING indicator light stays on when the timer is running.

• The CLEAN touch pad is used to start the automatic 50 minute cleaning cycle.

The timer is used in three ways:

1. In the OFF position the steam generator stays at a low boil or “holding”

temperature.

2. When a cook time is set, the unit steams until the timer runs down to OFF.

Steaming stops, the DONE light (a red light on older models) comes on and

a beeper sounds.

3. With the timer turned to the ON position, the unit steams continuously. The

green light stays lit. The steamer will not time down.

WARNING

WHEN YOU OPEN THE DOOR, STAY AWAY

FROM THE STEAM COMING OUT OF THE

UNIT. THE STEAM CAN CAUSE BURNS.

WARNING

ALL POTENTIAL USERS OF THE EQUIPMENT

SHOULD BE TRAINED IN SAFE AND CORRECT

OPERATING PROCEDURES.

NO ATTEMPT SHOULD BE MADE TO

OPERATE THIS EQUIPMENT DURING

A POWER FAILURE.

Power

ON/OFF

Button

Power

Indicator

Light
Service

Indicator

Light
Clean

Button

Steamer

Timer

Ready

Indicator

Light

Delime

Indicator

Light

Hi Temp

Indicator

Light