28

Installing an Optional Management Module

To install an optional management module, perform the following procedure:

Warning
Installing an optional management module while the chassis is powered
ON could result in damage to the module.

1.

Power OFF the chassis by performing one of the following:

For an AC model, unplug the power cord from the power outlet and
then unplug the power cord from the chassis.

For a DC model, follow the steps below:

Warning
When installing this equipment, always ensure that the frame ground
connection is installed first and disconnected last.

! 18

a. Remove the positive and negative feed wires from the terminal block

by loosening the screws to the wire connection with a flathead
screwdriver.

b. Remove the frame ground wire from the terminal block by loosening

the screw to the wire connection with a flathead screwdriver.

2.

Remove the blank faceplate covering the management module expansion
slot by loosening the two thumbscrews. See Figure 22.

Figure 22 Removing the Management Module Blank Faceplate

PWR 2

PWR 1

PBPWRA

C

AC IN

PUT

100-2

40AC

50-60

Hz

3A MA

X.

150W

PBPWRA

C

AC INPU

T

100-2

40AC

50-60

Hz

3A MA

X.

150W