beautypg.com

Power supply, Ac power supply – Allied Telesis AT-PBC18 User Manual

Page 14

background image

4

Power Supply

The PowerBlade PBC18 can be either an AC or DC powered chassis. The
expansion slot for the main power supply and the optional redundant power
supply are located on the back of the chassis. Refer to Figure 2.

The main and redundant power supply can be “hot swapped,” meaning that
should either power supply fail, the failed power supply can be removed and
replaced with a new power module while the chassis is operating. Network
operations will not be interrupted. The power modules to be hot swapped must
be the same type. For example, both power supplies must be AC or both must
be DC.

Powering ON or OFF the chassis depends on the type of power supply
installed. For an AC model, you connect or disconnect the power cord. For a
DC model, you connect or disconnect the DC power cables or power OFF the
DC circuit to which the power supply is connected.

For instructions on hot swapping, refer to “Hot Swapping a Power Supply” on
page 25
.

AC Power Supply

The AC power supply operates at 100-120/200-240 V AC with an input
frequency of 50/60 Hz at

±

3%. Figure 3 shows an PowerBlade PBC18 with an

AC power supply.

Figure 3 PowerBlade PBC18 with an AC Power Supply

PWR 2

PWR 1

PBM02

Management

MDI-X

MDI

LNK

STATUS

PWR

RESET

RS-232 Terminal

10Base-T

PBPWRAC

AC INPUT

100-240AC
50-60Hz
3A MAX.
150W