Collision Domain Diameters

A summary of the collision Domain Diameters is in Table 5:

Table 5: Collision Domain Diameters per IEEE Standard 802.3u

Note

The Collision Domain Diameter for a Class II repeater cannot exceed
205 meters. That is, the hub-to-device connection should never be
more than 100 meters and the inter-repeater should be 5 meters
(Note, however, that this inter-repeater link can be greater if all
device-to-repeater links are shortened. You simply have to ensure
that the Collision Domain Diameter remains at 205 meters.)

You are now ready to operate your AT-MR908TX hubs in a cascaded hub
configuration.

Model

All Copper

All Fiber

T4 and

Fiber

TX and

Fiber

DTE to DTE

100m

412m

na

na

1 Class I Repeater

200m

272m

231m*

260.8m*

1 Class II Repeater

200m

320m

304m*

308.8m*

2 Class II repeaters

205m

228m

236.3m**

216.2m**

*Assumes 100m of copper + one fiber link