beautypg.com

Connecting the telephone wires – Allied Telesis AT-iMG646PX-ON User Manual

Page 62

background image

Chapter 4: Installing the Gateway Outdoors

62

Section I: Outdoor Installation

the receive sensitivity specification. If the power is too high, an
optical attenuator is needed in the link. If the power is too low, you
must trace the optical path to determine the cause of the excess
loss.

Note

The AT-iMG646PX-ON WAN module has a receive sensitivity of -3
dBm to -26.5 dBm at 1490 nm. After the fiber pigtail is installed and
before you plug the pigtail into the gateway, please check the power
of the optical input signal. The power at 1490 nm should fall within
the receive sensitivity specification. If the power is too high, an
optical attenuator is needed in the link. If the power is too low, you
must trace the optical path to determine the cause of the excess
loss.

2. Connect the pigtail cable from the splice tray to the fiber port, using the

self-adhesive wire clips to secure the fiber cable to the gateway, as
shown in Figure 39.

Figure 39. Securing the Fiber Cable

Note

It is critical that you maintain a minimum fiber bend radius of 1 in.
when you route the fiber optic cables and mount them to the
gateway with the self-adhesive wire clips.

Connecting the

Telephone Wires

To connect the telephone wires, perform the following procedure:

1. Remove the grommet from the telephone wire entrance as shown in

Adhesive Clips

This manual is related to the following products: