AT-iMG646xx Series Intelligent Multiservice Gateway and AT-EN646 Enclosure Installation Guide

Section I: Outdoor Installation

37

4. Insert a UV-rated wire tie (not provided) through the slots at the bottom

of the entrance as shown in Figure 8.

Figure 8. Inserting the Wire Tie

5. Remove the grommet from the fiber optic drop cable and ground wire

entrance.

6. Strip the fiber jacket, per the cable manufacturer’s instructions, to 1.5

in. beyond the grommet slot where the cable will be coming into the
enclosure exposing 41 in. (104.14 cm) of buffer tube.

7. Locate the drop cable clamp on the grounding plate (see Figure 5 on

page 35) and remove the Kepnuts, washers, and bar from the posts.

8. Locate the strength member clamp (see Figure 5 on page 35) on the

grounding plate and loosen the Kepnuts.

9. Locate the aramid strand and trim it 6 in. (15.24 cm) from the

enclosure entrance.

10. Cut the cable strength member off 2.5 in. from the entrance to the

enclosure.

11. Position the cable so that the strength members go under the strength

member clamp, the jacket is about .25 in. beyond the drop cable clamp
posts, and the buffer tube is free, as shown in Figure 9.

Figure 9. Positioning the Cable