Chapter 9, Troubleshooting, R 9: troubleshooting – Allied Telesis x310 Series User Manual
Page 111

111
Chapter 9
Troubleshooting
This chapter contains suggestions on how to troubleshoot the switch if a
problem occurs.
Note
For further assistance, please contact Allied Telesis Technical
Support at www.alliedtelesis.com/support.
Problem 1: The Switch ID LED on the front of the switch is off.
Solutions: The unit is not receiving power. Try the following:
Verify that the power cord is securely connected to the power
source and to the AC connector on the back panel of the switch.
Verify that the power outlet has power by connecting another
device to it.
Try connecting the unit to another power source.
Try a different power cord.
Verify that the voltage from the power source is within the required
levels for your region.
Problem 2: All of the port LEDs are off even though the ports are
connected to active network devices.
Solution: The switch may be operating in the low power mode. To toggle
on the LEDs, press the eco-friendly button on the front panel of the switch.
You may also toggle the LEDs off and on with the ECOFRIENDLY LED
and NO ECOFRIENDLY LED commands in the command line interface.
Problem 3: The SHOW STACK command is not displaying all the
switches in the stack.
Solutions: One or more switches cannot join the stack. Try the following:
Verify that the stacking transceivers in the S1 and S2 slots of the
switches are properly cabled. The stacking cables must crossover
to different slots on the switches. For instructions, refer to Chapter
6, “Cabling the Stacking Ports” on page 83.
Verify that the transceivers are fully inserted into the S1 and S2
slots.