Allied Telesis IE200 Series User Manual
Page 64
Chapter 6: Troubleshooting
AT-IE200 Series Installation Guide
64
operation.
Note
A 1000Base connection may require five to ten seconds to establish a link.
Problem: The link/activity LED for an SFP transceiver is off.
Solution: The fiber optic port on the transceiver is unable to establish a link to a network device. Try the
following:
Verify that the network device connected to the fiber optic port is operating properly.
Verify that the fiber optic cable is securely connected to the port on the switch and to
the port on the remote network device.
Check that the SFP module is fully inserted in the slot.
Verify that the operating specifications of the fiber optic ports on the SFP transceiver
and the remote network device are compatible.
Verify that the correct type of fiber optic cabling is being used.
Verify that the port is connected to the correct fiber optic cable. This is to eliminate the
possibility that the port is connected to the wrong remote network device, such as a
powered off device.
Try connecting another network device to the fiber optic port using a different cable. If
the port is able to establish a link, then the problem is with the cable or with the other
network device.
Use the switch’s management software to verify that the port is enabled.
If the remote network device is a management device, use its management firmware to
determine whether its port is enabled.
Test the attenuation on the fiber optic cable with a fiber optic tester to determine
whether the optical signal is too weak (sensitivity) or too strong (maximum input
power).
Problem: Network performance between a twisted pair port on the switch and a network device is slow.
Solution: There might be a duplex mode mismatch between the port and the network device. This occurs
when a twisted pair port using Auto-Negotiation is connected to a device with a fixed duplex mode of full
duplex. If this is the cause of the problem, adjust the duplex mode of the port on the network device or on
the switch so that both ports are using the same duplex mode.
Problem: A port’s link/activity LED is blinking.
Solution: The link between the port and the network device is intermittent. Try the following:
Connect another network device with a different cable to the port. If the Link LED
remains steady on, then the problem is with the original cable or the network device.
If the problem is with an SFP transceiver, check that the transceiver is fully inserted in
the slot.