beautypg.com

Starting a local management session – Allied Telesis IE200 Series User Manual

Page 61

background image

Chapter 5: Powering on the Switch

AT-IE200 Series Installation Guide

61

Starting a Local Management Session

This procedure requires a terminal or a terminal emulator program and an RJ-45 management cable. To start
a local management session on the switch, perform the following procedure:

1. Connect the RJ-45 connector on the management cable to the console port on the front panel of the

switch.

2. Connect the other end of the cable to an RS-232 port on a terminal or PC with a terminal emulator

program.

3. Configure the terminal or terminal emulator program as follows:

Baud rate: 9600 bps (The baud rate of the console port is adjustable from 1200 to
115200 bps. The default is 9600 bps.)

Note

The BootLoader can only be managed at 9600 bps. If you set the baud rate to 115200 bps the
BootLoader will not work.

Data bits: 8

Parity: None

Stop bits: 1

Flow control: None

Note

The port settings are for a DEC VT100 or ANSI terminal, or an equivalent terminal emulator program.

4. Press Enter. You are prompted for a username and password.

5. Enter the username and password to log on the switch. If this is the initial management session of the

switch, enter “manager” as the user name “friend” as the password. The user name and password are
case sensitive.

The local management session starts when the AlliedWare Plus™ command line prompt is displayed.