Allied Telesis IE200 Series User Manual
Page 39
Chapter 2: Beginning the Installation
AT-IE200 Series Installation Guide
39
Warning
Do not work on equipment or cables during periods of lightning activity.
E2
Warning
Power cord is used as a disconnection device. To de-energize the equipment, unplug the power
connector from the unit.
Warning
This equipment must be earthed. The ground lug on the switch must be connected to a properly
earthed bonding point.
Note
Ground resistance from the building primary bonding point to earth should be less than 25 ohms.
Caution
A minimum of 4 inches open space shall be provided underneath the unit.
A minimum of 8 inches open space shall be provided on top of the unit.
A minimum of 4 inches open space shall be provided in front of the unit.
A minimum of 1” distance shall be kept between the sides of the unit and adjacent equipment.
Note
All Countries: Install product in accordance with local and National Electrical Codes.
E8
Warning
Operating Temperature. Maximum ambient temperature is installation dependent. Please see
“Environmental Specifications” on page 67 for details.
Warning
Only trained and qualified service personnel are allowed to install or to replace this equipment.
Caution
Circuit Overloading: Consideration should be given to the connection of the equipment to the supply
circuit and the effect that overloading of circuits might have on over current protection and supply
wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this
concern.
E21