Chapter 3, Troubleshooting, Chapte – Allied Telesis AT-GS950/10PS User Manual
Page 57

57
Chapter 3
Troubleshooting
This chapter contains information on how to troubleshoot the switch if a
problem occurs.
Note
For further assistance, please contact Allied Telesis Technical
Supp
Problem 1: The POWER LED on the front of the switch is off.
Solutions: The unit is not receiving power. Try the following:
Verify that the power cord is securely connected to the power
source and to the AC connector on the back panel of the switch.
Verify that the power outlet has power by connecting another
device to it.
Try connecting the unit to another power source.
Try a different power cord.
Verify that the voltage from the power source is within the required
levels for your region.
Problem 2: All of the port LEDs are off even though the ports are
connected to active network devices.
Solution: The switch is probably operating in low power mode. To toggle
on the LEDs, press the eco-friendly button on the front panel.
Caution
Pressing the eco-friendly button for more than 4 seconds causes the
switch to reboot. The switch does not forward network traffic during
the reboot process. Some network traffic may be lost. Pressing the
eco-friendly button for more than 10 seconds causes the switch to
reset to factory defaults.
Problem 3: A twisted pair port on the switch is connected to a network
device but the port’s LINK/ACT LED is off.
Solutions: The port is unable to establish a link to a network device. Try
the following:
Verify that the network device connected to the twisted pair port is
powered on and is operating properly.