beautypg.com

12 vdc regulator and power supply, Specifi cations – Campbell Scientific Solar1000 Station User Manual

Page 57

background image

CH100 and PS100

12 Vdc Regulator and Power Supply

Specifi cations*

Output

Voltage:

12 Vdc

Nominal

Capacity:

7 Amp hours

Input

Voltage

(CHG

terminals):

15 to 28 VDC or 18 VAC RMS

Battery

Connections

Charging

Output

Voltage:

Temperature compensated

fl oat charge for battery

Temperature

Compensation

Range:

-40º to +60ºC

Max. Charging Current:

1.2 A (allows one SP20 or SP10

to

be

used)

Power Out (+12 terminals)

Voltage:

Unregulated 12 V from battery

Temperature

Current

Limited

with

3

A

Thermal

Fuse:

> 3 A @ < 20°C; 3 A @ 20°C;

2.1A @ 50°C; 1.8 A @ 60°C

CH100

Weight:

5.5 oz. (158 g)

CH100

Dimensions

Height:

4.0” (10.2 cm)

Width:

2.76” (7.0 cm)

Depth:

1.5” (3.9 cm)

PS100

Weight:

6.9 lb (3.1 kg)

PS100 Dimensions (including mounts and connectors)

Height:

4.1” (10.5 cm)

Width:

7.6” (19.0 cm)

Depth:

2.8” (7.0cm)

The PS100 is used with our CR800, CR850, or CR1000 datalog-
gers. It includes a rechargeable battery and a regulator.

The CH100 controls the current fl owing to the battery and pre-
vents the battery current from fl owing to the charging source.